Exploring the Prevalence of Microorganisms in Selected Water Sources in Benue South of Nigeria using Selected Environmental Factors and Microbial Counts

Edegbene, Augustine O. and Yandev, Doowuese and Omotehinwa, Temidayo O. and Zakari, Hajara and Andy, Blessing O. and Ujoh, John A. (2024) Exploring the Prevalence of Microorganisms in Selected Water Sources in Benue South of Nigeria using Selected Environmental Factors and Microbial Counts. International Journal of Pathogen Research, 13 (3). pp. 36-45. ISSN 2582-3876

[thumbnail of Edegbene1332024IJPR116120.pdf] Text
Edegbene1332024IJPR116120.pdf - Published Version

Download (301kB)

Abstract

In this study, we assessed the water and microbial qualities of major water sources in nine sites within three Local Government Areas (LGAs-Otukpo, Ohimini and Apa LGAs) in Benue South between January and March, 2023. Water samples were collected monthly for the analyses of selected physico-chemical variables and microbial constituents in the studied sites following standard procedures. The results of the physico-chemical variables showed that most of the variables were proportionately higher than the maximum standards by appropriate regulatory bodies. For instance, electrical conductivity (EC) was highest in S2-Upu borehole, Otukpo LGA (1,181+285 µS/cm) and lowest in S4-Okpokwu River, Ohimini LGA (19.35+6.35 µS/cm). The concentration of dissolved oxygen (DO) in all the sites showed less aerated water except for S2 (5.37+0.34 mg/l) and 5S-Awulema borehole, Ohimini LGA (5.06+0.14 mg/l). On the microbial quality, the results of the total coliform counts from the nine sampling sites (water sources) showed that the highest coliform count (>1,600 MPN/100mL) was recorded in S1 in January 2023 while the lowest coliform count (12 MPN/100mL) was recorded in S2. The total bacteria viable counts (TVC) detected in the water sources sampled in the three LGAs in showed that the highest bacteria count (204 cfu per mL) was recorded in S3-Depot well, Otukpo LGA in January 2023, and the lowest bacteria count (36 cfu per mL) was recorded in S2 in January 2023. Escherichia coli was the most prevalent bacteria as it occurred in all the sites sampled except S6- Ijami well, Ohimini LGA and S9- Amoke well, Apa LGA. Our finding based on the concentration of pollution indicating physico-chemical variables (e.g., EC, BOD5, and COD) showed the water sources studied in the three LGAs in Benue South were relatively perturbed. This was also confirmed by the prevalence of microbial loads which in most cases exceeded the minimum standard set by WHO for drinking water.

Item Type: Article
Subjects: ScienceOpen Library > Medical Science
Depositing User: Managing Editor
Date Deposited: 11 May 2024 06:34
Last Modified: 11 May 2024 06:34
URI: http://scholar.researcherseuropeans.com/id/eprint/2420

Actions (login required)

View Item
View Item